TPB3LE-63 RCBO Breaker for Overload and Leakage Safety

Rated short-circuit capacity Icn:TPB3LE-63:4.5kA(63Y:6kA)/Standard: IEC 61009-1

TPB3LE-63 Residual Current Circuit Breaker with Overcurrent protection(RCBO) combines overload, short circuit and residual current protection in one compact breaker. It is used in distribution boards where both personal safety and circuit protection are required. The key value is saving panel space, simplifying wiring design and reducing the risk of electric shock, leakage faults and equipment damage.

TPB3LE-63 RCBOs are intended for AC 50/60 Hz systems, up to 400 V and 63 A. They combine leakage (RCD) and overcurrent protection to help protect people from electric shock and minimize fire risk due to earth leakage.
Products Categories
Get A Free Quote
Contact Form

TPB3LE-63 RCBO Features

  • Protection against overload and short-circuit currents.
  • Protection against the effects of sinusoidal alternating earth fault currents.
  • Protection against indirect contacts and additional protection against direct contacts.
  • Protection against fire hazard caused by insulation faults.
  • Used in residential building.
  • According to the type of instantaneous release classified as follows : type B(3-5)In, type C(5-10)In, type D(10-20)In.

Type designation

TPB3LE-63 1P+N C63A 100mA

TP B3 LE 63 1P+N C 63A 100mA
Company code Series code Electronic residual current protection Frame Poles Curve Current(In) Rated sensitivity IΔn
TP B3 LE 63 1P+N 2P 3P 3P+N 4P B C D 6A~63A 30mA 50mA 100mA 300mA

Note: Breaking capacity:4.5kA This product can be assembledwithaccessories(TPB3-63 OF/SD/OF+SD/MX/MVMN/MX+OF,etc)

Technical data

Type Parameter Unit Specification
– Standard – IEC/EN 61009-1
Electrical Features Poles P 1P+N,2P,3P,3P+N,4P
Type(wave form of the earth leakage sensed) – AC
Thermomagnetic release characteristic – B,C,D
Rated current In A 6,10,16,20,25,32,40,50,63
Rated voltage Ue V 230V AC(1P+N,2P)400V AC(3P 3P+N,4P)
Rated sensitivity IΔn A 0.03,0.05,0.1,0.3
Rated residual making and breaking capacity IΔm A 500(In≤40A) 630(In>40A)
Rated short-circuit capacity Icn A 4500
Break time under IΔn s ≤0.1
Rated frequency Hz 50/60
Rated impulse withstand voltage(1.2/50)Uimp V 4000
Dielectric test voltage at ind.Freq.for 1min Kv 2
Insulation voltage Ui V 500
Pollution degree – 2
Mechanical Features Electrical life times 4000
Mechanical life times 10000
Contact position indicator – Yes
Protection degree – IP20
Storage temperature ℃ -25~+70
Installation Terminal connection type – Cable/Pin-type busbar
Terminal size top/ bottom for cable mm² 25
AWG 18-3
Terminal size top/ bottom for busbar mm² 25
AWG 18-3
Tightening torque N*m 2
In-lbs 18
Mounting – On DIN rail EN60715(35mm)by means of fast clip device
Connection – From top
  • Operating conditions

1.Ambient temperature: -5°C~+40°C

2.Relative humidity: ≤50% at 40°C; ≤90% at 25°C

3.Altitude: ≤2000m

4.Environmental conditions: no harmful gases and vapors, no conductive or explosive dust, no severe mechanical vibration

TPB3LE-63 RCBO Selection

Curve Type Test current Tripping time Expected result
B,C,D 1.13In t≤1h(In≤63A) Not tripping
1.13In t≤2h(In>63A)
B,C,D 1.45In t≤1h(In≤63A) Tripping
1.45In t<2h(In>63A)
B,C,D 2.25In 1s<t<60s(In≤32A) Tripping
2.25In 1s<t<120s(In>32A)
Curve Type Test current Tripping time Expected result
B 3In t≤0.1s Not tripping
C 5In t≤0.1s
D 10In t≤0.1s
B 5In t<0.1s Tripping
C 10In t<0.1s
D 20In t<0.1s
  • Curve

Curve-of-TPB3LE-63-RCBO

Overall and mounting dimensions(mm)

Overall-and-mounting-dimensions-of-TPB3LE-63-RCBO

Related Products

Related News

Scroll to Top

Get Your Quote Within 24 Hours

Contact Form
Our engineering team will reply with a tailored quotation and confirmed lead time within 24 hours.
Get A Free Quote

Get Your Quote Within 24 Hours

Contact Form (#6)
Our engineering team will reply with a tailored quotation and confirmed lead time within 24 hours.
Get A Free Quote