TPW3 Series ACB Air Circuit Breaker for Low Voltage Distribution

Reliable low voltage air circuit breaker for intelligent circuit protection and power distribution in industrial, commercial, and building electrical systems.

The TPW3 Series ACB air circuit breaker is engineered for low-voltage power distribution systems requiring reliable protection and stable operation. Suitable for AC 50/60Hz systems with rated voltages of 400V and 690V and current ratings from 200A to 6300A, it provides effective protection against overload, short-circuit, undervoltage, and earth fault conditions. With intelligent and selective protection functions, it helps improve electrical system safety, maintain power continuity, and reduce unnecessary downtime. Widely used in industrial plants, power stations, mines, and smart building projects, the TPW3 air circuit breaker meets IEC/EN 60947-2 standards.

Products Categories
Get A Free Quote
Contact Form

Frame-type circuit breaker Type designation

TPW3- □/□ + Installation + Control unit + Common use accessory + Optional accessory

TP W3 □ □ Installation Control unit Common use accessory Optional accessory
Company code Series code Rated current in scope of frame size Poles Installation Intelligent controller Common use accessory Optional accessory
TP W3 1600 Type In: 200A,400A,630A,800A,1000A,1250A,1600A

2000 Type In:630A,800A,1000A,1250A,1600A,2000A

2500 type In:630A,800A,1000A,1250A,1600A,2000A,2500A

3200 Type In: 2000A,2500A,3200A

4000 Type In: 2500A,3200A,4000A

6300 Type In:4000A,5000A,6300A

3-3 pole(default)
4-4 pole
Fixed type-horizontal
Drawout type-horizontal, vertical(Default horizontal wiring)
M type2M type: digital display, over-current protection (overload,short delay, instantaneous),4P or 3P+N have earthing protection.

3M type: LCD display, over-current protection(overload,short delay,instantaneous), 4P or 3P+N have earthing protection.

H type2H type: communication function, digital display, over-cur-rent protection(overload,short delay, instantaneous), 4P or 3P+N haveearthing protection.

3H type:communication function, LCD display, over-cur-rent protection (overload,short delay,instantaneous),4P or 3P+N have earthing protection.

Shunt release-AC220V/230V,AC380V/400V,DC220V,DC110V

Undervoltage release-AC220V/230V,AC380V/400V,

it is classified to instanta-neous type and time-delay type.

Closing electromagnet-AC220V/230V,AC380V/400V,DC220V,DC110V

Motor-driven energy-storage mecha-nism-AC220V/230V,AC380V/400V,DC220V,DC110V

Auxiliary contact-4a4b,2a6b,3a3b

Note: a-normal open, b-normal close

Mechanical interlock;

One circuit breaker(1lock+1key)

Two circuit breakers(steel cablenterlock, connecting rod inter-ock,2lock+ 1key)

Three circuit breakers(3lock+2keys,connecting rodnterlock)

Automatic power transfer systemCurrent transformer connectedwith neutral load

TPW3 ACB Air Circuit Breaker Technical Data

Item Description
Number of Poles 3,4
Rated voltage Ue(V) 400/415,660/690
Rated insulation voltage Ui(V) 1000
Rated impulse withstand voltage Uimp(kV) 12
Rated frequency(Hz) 50/60
Have function of switch disconnector TPW3 ACB switch disconnector description

 

  • Frame size rated current
Rated current In(A) 1600 2000 2500 3200 4000 6300
200 ●
400 ●
630 ● ● ●
800 ● ● ●
1000 ● ● ●
1250 ● ● ●
1600 ● ● ●
2000 ● ● ●
2500 ● ● ●
3200 ● ●
4000 ● ●
5000 ●
6300 ●

 

  • Operating conditions
Item Description
Ambient temperature -5℃~+40℃;the average value within 24h shall not exceed +35℃; L type and M type controller can be used under
-40℃~+70℃
Altitude ≤2000m
Pollution grade 3
Safety category Main circuit and undervoltage tripping coil is IV,other auxiliary and control circuit is III
Installation position Vertically installed,inclination between the mounting plane and the vertical plane should not exceed ±5°

 

  • Breaking capacity
Rated current In(A) 1600 2000 2500 3200 4000 6300
Rated ultimate short circuibreaking capacity Icu(kA) 400/415V 65 80 100 100 120 135
660/690V 50 65 70 85 85 100
Rated service short circuit breaking capacity Ics(kA) 400/415V 55 65 80 80 100 135
660/690V 42 65 70 70 85 100
Rated short time withstand current Icw.1s(kA) 400/415V 50 65 80 80 100 135
660/690V 42 65 70 70 85 100
Rated short circuit making and breaking capacity Icm(kA) 400/415V 110 176 220 220 264 297
660/690V 77 143 154 154 187 220
Electric life 8000 8000 8000 8000 600 1500
Mechanical life (Maintenance) 30000 30000 30000 20000 20000 5000
Mechanical life (Non-maintenance) 20000 15000 15000 12500 10000 2500
Dimension(mm) W×H×L
Drawout type 3P 254×297×354 375×389×432 375×389×432 435×389×432 435×389×432 813×389×432
4P 324×297×354 470×389×432 470×389×432 550×389×432 550×389×432 928×389×432
Fixed type 3P 269×195×324 362×293×401 362×293×401 426×293×401 426×293×401 807×293×401
4P 339×195×324 457×293×401 457×293×401 537×293×401 537×293×401 922×293×401

Note:6300A only has 3P drawout type.

 

  • Protection features of intelligent controller
Digital display intelligent controller Air-circuit breaker-TPW3-ACB-M(H)-type-controller
M type: digital display without communication H type: digital display with communication
01. bottom fixing position
02. rated current
03. digital display window
04. “set” switch to setting menu
05. base plate
06. indicator
LCD display intelligent controller Air-circuit breaker-TPW3-ACB-3M3HLCD-controller
3M type: LCD display without communication 3H type: LCD display with communication
01. bottom fixing position
02. rated current
03. digital display window
04. “set” switch to setting menu
05. base plate
06. indicator
M/H (standard type) intelligent controller Air-circuit breaker-TPW3-ACB-MH-(standard-type)-intelligent-controller
01. Current of phase A 13. +/up
02. Current of phase B 14. Enter
03. Current of phase C 15. -/down
04. Current of phase N 16. Function keys
05. Load monitoring 2 17. Return
06. Load monitoring 1 18. Set indicator
07. Unbalanced current protection 19. Check indicator
08. Earth fault protection 20. Save indicator
09. Self-diagnosis by the intelligent controller 21. Test indicator
10. Short circuit instantaneous protection 22. Alarm indicator
11. Short circuit short-time delay protection 23. Fault indicator
12. Overload long-time delay protection
3M/3H(LCD) intelligent controller Frame-type-TPW3-ACB-3M(3H)type-LCD-controller
01. -/down 09. Overload long-time delay protection
02. +/up 10. Run indicator
03. Set 11. Communication indicator
04. Check 12. Short circuit short-time delay protection
05. Return 13. Earth fault protection
06. Enter 14. Alarm indicator
07. Test 15. Over-voltage protection
08. Reset 16. Short circuit instantaneous protection

Ordering information

Quantity Set
Model Available type and rated current Rated voltage □ AC400V □ AC690V
TPW3-1600 □ 200 □ 400 □ 600 □ 800 □ 1000 □ 1250 □ 1600 Quantity Set □ Fixed  □ Draw-out □Three poles □Four poles
TPW3-2000 □ 630 □ 800 □ 1000 □ 1250 □ 1600 □ 2000 Quantity Set □ Fixed  □ Draw-out □Three poles □Four poles
TPW3-2500 □ 630 □ 800 □ 1000 □ 1250 □ 1600 □ 2000 □ 2500 Quantity Set □ Fixed  □ Draw-out □Three poles □Four poles
TPW3-3200 □ 2500 □ 2900 □ 3200 Quantity Set □ Fixed  □ Draw-out □Three poles □Four poles
TPW3-4000 □ 3200 □ 3600 □ 4000 Quantity Set □ Fixed  □ Draw-out □Three poles □Four poles
TPW3-6300 □ 4000 □ 5000 □ 6300 Quantity Set □ Fixed  □ Draw-out □Three poles □Four poles
Intelligent controller Basic function □ Overload long time delay protection □ Short-circuit short delay □ Short-circuit instantaneous
Other function □ Earthing protection □ Load monitoring □ Ampere meter □ MCR function □ Thermo-simulating □ voltage meter □
Self-diagnosis □ Testing □ Fault records □ Communication
Controller power □ AC 220V □ AC 380V □ DC 220V □ DC 110V
Standard configuration □ Shunt release □ Under-voltage instantaneous type
□ Under-voltage time-delay type □ 1s □ 3s □ 5s □ 10s
□ Closing electromagnet □ AC 220V □ AC 380V □ DC 220V □ DC 110V
□ Motor-driven energy-storage mechanism
□ Auxiliary contact □ 4 groups of changeover contacts
Optional configuration □ Under-voltage release □ AC 220V □ AC 380V
□ Auxiliary contact □ 2NO adn 6NC contacts □ 4NO and 4NC contacts □ 6NC and 4NO contacts □ 3NO and 3NC contacts (TPW3-1600 noly have
4 groups of changeover contacts)
□ Locking device □ Horizontal interlock □ Vertical interlock □ Door interlock □ Others

Note:
1. The frame size current, rated current and auxiliary control voltage must be specified when ordering.

2. Please mark “√” or fill in figure in the relative “□”, if no mark, we will provide as usual.

3. The operational function of the intelligent controller and special requirement require additional cost

Related Products

Related News

Scroll to Top

Get Your Quote Within 24 Hours

Contact Form
Our engineering team will reply with a tailored quotation and confirmed lead time within 24 hours.
Get A Free Quote

Get Your Quote Within 24 Hours

Contact Form (#6)
Our engineering team will reply with a tailored quotation and confirmed lead time within 24 hours.
Get A Free Quote